Thank you for choosing an Aquamor® UF Series Ultrafiltration System. Designed and assembled in the USA, the UF Series provides reliable, high-performance water filtration for commercial and residential applications. Every system is manufactured from premium materials, assembled to strict quality standards, and factory tested before shipment to ensure dependable operation. This owner's manual contains important information regarding the installation, operation, and maintenance of your system. Please read it completely before installing or operating the unit, and retain it for future reference.
If you have any problems with the installation or operation of your water filtration system, please contact us at (866) 218-8473 (toll-free) or 951-541-9517 (direct).
Fill in the information below and have it ready when calling for assistance. The serial number can be found on the specification plate located on the system.
Read all instructions before use. Save these instructions. Review this owner's manual before installing or operating the ultrafiltration system, and keep it for future reference. Use the system only for its intended use as outlined in this manual. Only qualified personnel should service the system.
Electric shock hazard. Contact with a damaged cord, plug, or wiring can cause serious injury or death. Install this system on a ground fault circuit interrupter (GFCI) protected circuit, follow all local electrical codes, unplug the power cord before servicing, and do not operate with a damaged cord or plug. Never immerse the power cord or plug in water. Keep the power cord away from hot surfaces. Do not modify the power cord or use an extension cord. If the cord is damaged, contact the manufacturer, its service agent, or a qualified electrician.
High-pressure water hazard. Operating above rated pressure can rupture the system or fittings and cause injury from flying debris or pressurized water. Do not allow water pressure to exceed 125 psig (862 kPa); install a pressure regulator if necessary. Do not allow the trans-membrane pressure to exceed 45 psi (310 kPa). Protect the system from pressure surges or water hammer, using a water hammer arrestor on the inlet side if necessary. Depressurize the system before servicing.
Chemical hazard. Liquid chlorine bleach and chlorine-based sanitizer concentrate can cause burns to skin and eyes and harmful fumes if mishandled. When sanitizing, wear suitable eye and skin protection, work in a ventilated area, do not mix the sanitizer with other chemicals, and follow all safety instructions supplied with the sanitizer.
Health hazard. This system is not a microbiological purifier and will not make unsafe water safe to drink. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Use only on municipal or well water sources that are treated and tested on a regular basis to ensure bacteriologically safe quality. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Hot water hazard. Connecting this system to a hot water line can cause scalding burns. This system is designed for cold-water applications only. Connect only to a cold water supply and do not apply heat to the system when soldering nearby plumbing.
Equipment damage. Hot water will damage the system. Use only with cold water.
Equipment damage. Improper handling or exposure can permanently damage the UltraFilter membrane and plastic parts. Keep the UltraFilter wet and sealed at all times and do not allow it to dry out. Do not allow the system to freeze during operation or storage. Avoid long-term exposure to direct sunlight or other UV sources. Do not drop or bump the system; handle carefully during transport and installation. Do not use strong solvents, chlorine-containing solvents, concentrated acids, abrasive cleaners, or sharp objects on the membrane or plastic parts. Flush all pipes before installing the system to remove abrasive material.
Installation requirement. If the system is installed on metallic plumbing, an electrical bonding jumper must be installed across the inlet and outlet pipes, and all local plumbing codes must be followed. Failure to bond may interrupt the electrical grounding continuity of the metallic plumbing system.
All AQUAMOR products are constructed of the finest materials available and manufactured to high quality standards. Complete Water Filtration and Water Treatment Systems (excluding water filters and water treatment replacement cartridges) are warranted to be free from defects in materials and workmanship for a period of Five (5) years from date of purchase, under normal use and service, and when installed in accordance with AQUAMOR's recommendations outlined in the filtration systems owner's manual. Service Replacement Parts (cartridges, filter elements, feeder elements, etc.) are warranted to be free from defects in materials and workmanship for a period of one (1) year from the date of purchase or the remainder of the original warranty, whichever is longer. Discrete Components (flow restrictors, drain saddles, mounting clips, automatic check valves, etc.) are warranted for a period of Ninety (90) days from the date of purchase.
The UF System Controller and other electronics are covered under this warranty for five (5) years from the date of shipment when shipped as part of a complete Aquamor UF System. When the controller is sold or shipped separately, it is covered for one (1) year from the date of shipment. This warranty does not cover water damage to the controller or other electronics.
All warranty claims must be submitted to Aquamor within the applicable warranty period.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REMEDIES DESCRIBED ABOVE ARE EXCLUSIVE, AND IN NO EVENT SHALL AQUAMOR BE LIABLE FOR SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF THIS WARRANTY.
Overall dimensions shown in inches. Four models are available in single- and dual-membrane, 20″ and 40″ configurations.
| Model | Configuration | Width | Height | Depth |
|---|---|---|---|---|
| UF-4210-0000 | Single membrane, 20 inch | 9.2 in (234 mm) | 41.68 in (1059 mm) | 8.25 in (210 mm) nominal 9.125 in (232 mm) max. |
| UF-4220-0000 | Dual membrane, 20 inch | 14.45 in (367 mm) | 41.68 in (1059 mm) | 8.25 in (210 mm) nominal 9.125 in (232 mm) max. |
| UF-4410-0000 | Single membrane, 40 inch | 9.2 in (234 mm) | 60.52 in (1537 mm) | 8.25 in (210 mm) nominal 9.125 in (232 mm) max. |
| UF-4420-0000 | Dual membrane, 40 inch | 14.48 in (368 mm) | 60.52 in (1537 mm) | 8.25 in (210 mm) nominal 9.125 in (232 mm) max. |
| Item | Rating |
|---|---|
| Power adapter | Universal power adapter; includes four interchangeable plug adapters |
| Input (AC) | 100-240 VAC, 0.4 A, 47-63 Hz |
| Output to controller (DC) | 24.0 V DC, 0.4 A, 9.6 W |
The power adapter takes AC input from the wall outlet and supplies 24 V DC output to the controller.
Certified System Models: UF-4210-0000, UF-4220-0000, UF-4410-0000, UF-4420-0000
Tested and Certified by NSF International against NSF/ANSI Standard 53 for cyst reduction.
The concentration of the indicated substance in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standard 53.
| Parameter | Value |
|---|---|
| Minimum Pressure | 20 psi (1.4 bar) |
| Recommended Minimum Pressure | 50 psi (3.4 bar). Aquamor recommends a booster pump on any inlet pressure below 50 psi, to bring it to a minimum of 50 psi for more consistent flow and flushing of the UF membranes. |
| Maximum Pressure | 125 psi (8.6 bar) |
| Minimum Temperature | 40°F (4.4°C) |
| Maximum Temperature | 100°F (38°C) |
| pH Range | 3–10 |
| Max. Trans-Membrane Pressure | 45 psi (3.1 bar) |
| Contaminant | Challenge Concentration (count/L) | NSF Required Reduction | Achieved Reduction |
|---|---|---|---|
| Cyst | >50,000 | 99.95% | 99.99% |
In plain terms: when test water was challenged with more than 50,000 cysts per liter, the system removed 99.99% of them, better than the 99.95% reduction NSF requires.
| System Model Number | UF Membrane Dia. | UF Membrane Length | No. of Membranes | Service Flow GPM (LPM) | Replacement Membrane | Part No. |
|---|---|---|---|---|---|---|
| UF-4210-0000 | 4″ | 20″ | 1 | 8 (30.28) | AQ UF-20 | 305513 |
| UF-4220-0000 | 4″ | 20″ | 2 | 16 (60.57) | AQ UF-20 | 305513 |
| UF-4410-0000 | 4″ | 40″ | 1 | 15 (57.78) | AQ UF-40 | 305511 |
| UF-4420-0000 | 4″ | 40″ | 2 | 30 (113.56) | AQ UF-40 | 305511 |
Replacement UltraFilter membranes: AQ UF-20 (20 inch), Part No. 305513 and AQ UF-40 (40 inch), Part No. 305511. Service flow rates shown; peak flow may vary with inlet pressure and water conditions.
Certified base systems: UF-4210-0000, UF-4220-0000, UF-4410-0000, UF-4420-0000. The final four digits identify the system configuration or private-label series. Under NSF's Commercial Modular certification program, any model number built on one of these certified base platforms (for example, UF-4210-####) is produced from the same certified components and carries the same NSF/ANSI 53 cyst-reduction certification.
Before you begin, confirm the system shipped with the connection hardware listed below. Order any missing item by part number before starting the installation.
Group A: Connection Fittings and Gauge Ports
| Item | Qty | Part No. | Notes |
|---|---|---|---|
| 1 in. NPT Fitting with O-Rings and Gauge Port | 2 | 306067 | Supplied with 500007 pressure gauges installed. |
| 3/4 in. NPT Fitting with O-Rings and Gauge Port | 2 | 306037 | Additional (spare) fittings. |
| 3/4 in. Garden Hose Adapter | 1 | 304629 | Connects to the manual ball valve to flush the UltraFilter membrane(s) at initial start-up. |
Group B: Flow Restrictor
Flow restrictor fitted per model, where applicable:
| System Model | Flow Restrictor | Part No. |
|---|---|---|
| UF-4210-0000 (single membrane, 20 in.) | 8 GPM | 502806 |
| UF-4220-0000 (dual membrane, 20 in.) | 15 GPM | 502809 |
| UF-4410-0000 (single membrane, 40 in.) | 15 GPM | 502809 |
| UF-4420-0000 (dual membrane, 40 in.) | None installed | — |
UF-4420-0000 does not use a flow restrictor. Flow on this model is limited to 30 GPM by the system's pipe size.
Group C: Electric Drain Ball Valve(s)
| Item | Part No. | Thread | Notes |
|---|---|---|---|
| Electric Ball Valve | 503043 | 3/4 in. NPT female threads | Connects to the drain line. |
Quantity is one electric ball valve per UF membrane. Single-membrane models include one valve; dual-membrane models include two. Each system includes one controller, which operates one or two electric ball valves depending on the number of membranes.
| System Model | UF Membranes | Electric Ball Valves (P/N 503043) |
|---|---|---|
| UF-4210-0000 | 1 | 1 |
| UF-4410-0000 | 1 | 1 |
| UF-4220-0000 | 2 | 2 |
| UF-4420-0000 | 2 | 2 |
Dual-membrane systems ship with two membrane manifold assemblies that are joined to each other at the manifold heads. UF systems are installed in parallel only; Aquamor does not sell serial-flow configurations. Single-membrane systems have one manifold and no manifold-to-manifold connection.
| Configuration | System Models | Manifold-to-Manifold Connection | Connection Hardware |
|---|---|---|---|
| Single membrane | UF-4210-0000 UF-4410-0000 | Not applicable. One membrane manifold, no interconnect. | None. The union fitting P/N 306034 is not listed on the parts list for either single-membrane model. |
| Dual membrane (parallel flow, always) | UF-4220-0000 UF-4420-0000 | Two union fittings join the upper manifold heads and one union fitting joins the lower manifold heads. Feed water is divided between the two membranes, which operate side by side. | Three union fittings with O-rings, P/N 306034 (two upper, one lower). |
The line voltage must match the voltage on the specification label. The plug on the power cord must match the appropriate outlet. Do NOT connect the system to a switched electrical outlet.
Only connect the system to the cold water line. Do NOT connect it to the hot water line.
When making plumbing connections, use a back-up wrench on the supporting plumbing. Use pipe sealant or thread seal tape on pipe threads, but never allow pipe sealant inside the pipes.
For the 1 inch plastic NPT connections, wrap the male threads with PTFE thread seal tape and turn the fitting hand-tight plus 1 to 2 turns. Do not over-torque the plastic. If you use soldered plumbing with your system, do NOT apply heat to the filtration system.
Use the following recommendations when mounting your system.
To mount the system directly onto the wall:
To mount the system with the optional brackets:
The drain valve (electric ball valve) is used to flush accumulated debris from the system during self-cleaning.
To properly install the drain valve connection:
When making the drain valve connection, follow these guidelines:
Connect the UltraFilter rinse valve to a proper air-gap drain.
Do not overtighten the fittings, which could cause damage to the fittings. Hand-tight plus 1 to 2 turns is sufficient on the plastic NPT connections; do not over-torque.
When making connections to the system, use plastic fittings and a pipe thread sealant that is approved for use on PVC fittings.
Do not overtighten the fittings, which could cause damage to the fittings. Hand-tight plus 1 to 2 turns is sufficient on the plastic NPT connections; do not over-torque.
When making connections to the system, use plastic fittings and a pipe thread sealant that is approved for use on PVC fittings.
Install a tee fitting with plug before the system inlet, which can then be used to sanitize the system and any downstream plumbing.
Minimum inlet pressure is 20 psi. Aquamor recommends installing a booster pump on any inlet pressure below 50 psi, to bring supply pressure to a minimum of 50 psi for more consistent flow and flushing of the UF membranes.
Flush all supply plumbing thoroughly before connecting the system. Slowly open the inlet water valve while holding a bucket at the inlet line. Continue until all debris is removed from the pipe.
Installing an optional bypass on the system is recommended, as it will help with UltraFilter membrane replacement and servicing. To install a bypass:
The UltraFilter membrane ships inside the stainless steel vessel. It stays in its sealed sanitary plastic bag.
Before you use the system, remove the sanitary bag. Then install the membrane adapters.
Once the UltraFilter is installed, rinse it before you use the system. Rinsing removes trapped air and the protective storage solution.
(If a sanitation tee is installed in front of the inlet connection.)
Sanitize the plumbing after installation. This removes any contamination from the install.
You will need a sanitizer. Use one ounce (30 ml) of liquid chlorine bleach. You can also use a Kay-5 sanitizer solution or an equivalent.
To make the Kay-5 solution, dissolve a 1 oz. packet of Kay-5 powder in 2 oz. (60 ml) of clean warm water.
Confirm each item below before placing the system into service.
The system features two modes: Normal Operation Mode and Flush Mode.
In Normal Operation Mode, water enters the inlet and flows into the filter, then out the permeate outlet as usable water.
In Flush Mode, water enters the inlet and cleans the UltraFilter by removing any debris from the membrane wall.
Equipment damage. Interrupting power or water during Flush Mode stops the flush cycle while filtration continues, which can plug the UltraFilter. Do not unplug the power cord or shut off the water while the system is in Flush Mode.
During installation, or whenever a manual flush is desired independent of the programmed flush time(s), press and hold the LEFT and RIGHT arrow buttons simultaneously for 5 seconds. The display switches from the time-of-day display to the programming screen and counts down the flush; once the flush completes, the system automatically returns to the time-of-day display.
The controller directs the start time, interval, and duration of each membrane flush. It normally displays the time of day; during a flush it switches to the programming screen and counts down the flush duration.
The flush settings can be changed, though it is recommended to leave them at the default setting. The controller uses a 24-hour clock.
To change the settings on the UF controller:
The air charge on the system's permeate tank should be checked every 6 months. In order to check the charge, you will need the following items:
Intervals are typical starting points. Adjust to local water conditions and usage.
| Maintenance Item | Recommended Interval |
|---|---|
| Inspect plumbing connections for leaks | Monthly |
| Verify drain tubing is secure and unobstructed | Monthly |
| Verify the automatic flush cycle is operating properly | Monthly |
| Inspect the controller and power connections | Monthly |
| Check permeate tank pre-charge pressure | Every 6 months |
| Inspect UltraFilter membrane performance (flow and pressure drop) | Every 6 months or as needed |
| Replace UltraFilter membrane (AQ UF-20, Part No. 305513 for 20-inch systems; AQ UF-40, Part No. 305511 for 40-inch systems; see Replacement Parts) | When differential pressure (DP) is 25 psid or greater. See the note below. |
When the system reaches the end of its service life, decommission and dispose of it responsibly.
Equipment damage. The UltraFilter membrane will be permanently damaged if it freezes. The membrane cannot be drained to winterize; it must stay wet at all times. Protect it from freezing as described below.
If the system will be stored, shut down, or left in an unheated space, prepare it as follows.
Use the table below to diagnose common conditions. If a condition is not listed, persists after the listed action, or involves a leak you cannot stop, depressurize the system and contact Aquamor before continuing.
| Symptom | Likely Cause | Action | Stop and Call Aquamor If |
|---|---|---|---|
| Leak at a fitting or connection | Connection not seated, sealant or thread tape missing, or fitting over-torqued and cracked. | Depressurize the system (close inlet and outlet valves, open the rinse valve). Inspect the connection and reseat it with thread seal tape, hand-tight plus 1 to 2 turns. Do not over-torque the plastic. | The leak continues after reseating, a plastic part is cracked, or water reaches electrical components. |
| Leak from the body of a membrane housing or end cap | O-ring damaged or misseated, or end-cap clamp loose. | Depressurize the system. Inspect the O-rings for nicks; replace and lubricate with food-grade silicone as described under Maintenance, and re-seat the end caps and clamps. | The leak continues after service or the housing itself appears damaged. |
| Low or no flow at the outlet | Inlet valve partly closed, supply pressure low, system in Flush Mode, or membrane fouled. | Confirm the inlet valve is fully open and supply pressure is at least 20 psi (1.4 bar); a booster pump is recommended below 50 psi for consistent flow and flushing. Wait for any flush cycle to finish. If flow stays low, the membrane may need replacement. | Flow does not recover after these checks, or supply pressure cannot be brought into range. |
| Controller screen is blank or has no power | Power adapter unplugged, connected to a switched outlet, or harness not seated in the controller. | Confirm the adapter is plugged into a live, unswitched outlet and the power harness is fully seated in the left-most controller port. Verify the outlet with another device. | The screen stays blank with confirmed power, or the cord or adapter is damaged. |
| System will not flush | Power interrupted during a flush, flush settings changed, or drain line blocked. | Restore power. Initiate a manual flush (hold the LEFT and RIGHT arrows together for 5 seconds). Confirm the drain line is clear and not kinked, and review the flush settings under Maintenance. | The system still will not flush after power is restored and the drain is confirmed clear. |
| Cloudy water or off taste after startup or service | Trapped air, or storage solution not fully rinsed from a new membrane. | Complete the Rinsing the UltraFilter procedure in full, including the repeated manual flushes, then run water at the nearest tap until it clears. | Cloudiness or off taste remains after a complete rinse, or the source water quality is in question. |
| Water at the permeate tank air valve | The internal tank bladder has ruptured. | Depressurize the system. The permeate tank must be replaced; it cannot be repaired. | Water is present at the air valve. Replace the tank. |
Exploded views with itemized parts lists. Order replacement components by part number.